Wireless Leaf & Soil Moisture/Temperature Station
Installation Manual
For Wireless Vantage Pro2
and Vantage Pro2 Plus
The Wireless Leaf & Soil Moisture/Temperature Station (referred to in this document
as the Leaf/Soil Station) can be used with any Wireless Vantage Pro2 weather station
to measure leaf wetness, soil moisture, or temperature.
The following Vantage Pro2 console station configurations can be used with the
Leaf/Soil Station:
Only one Leaf/Soil Station can be installed as a Leaf/Soil Station per Vantage Pro2
Weather Station.
Two stations can be installed if one is configured as a Leaf Station and the other
station is configured as a Soil Station in the Vantage Pro2 console.
Configured as a Leaf Station, the Station supports two leaf wetness sensors and
two temperature probes.
Configured as a Soil Station, it supports up to four soil moisture sensors and tem-
perature probes.
Note: In any station using soil moisture sensors, the corresponding temperature probe, if installed, will be
used for temperature compensation of the soil moisture sensor.
Tools for Setup
In addition to the components shown, you will need some or all of the following
materials:
Adjustable wrench or 7/16" wrench
Medium Phillips Screwdriver
Ballpoint pen or paper clip (small pointed object of some kind)
Drill and 3/16" (5 mm) drill bit (if mounting on a vertical surface)
Stepped Sensor Installation Tool for Soil Moisture and Temperature Sensors (rec-
ommended, see page 16)
Station Type in
Console
Configuration
Number of Leaf
Wetness Sensors
Number of Soil
Moisture Sensors
Number of
Temp Probes
LEAF/SOIL Station 2 4 4
LEAF Station 2 - 2
SOIL Station - 4 4
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - and Vantage Pro2 Plus

1Wireless Leaf & Soil Moisture/Temperature StationInstallation ManualFor Wireless Vantage Pro2™ and Vantage Pro2 Plus™The Wireless Leaf & Soil

Seite 2 - Optional Sensors

102. Place a flat washer, a lock washer and a hex nut on each of the bolt ends. 3. Using an adjustable wrench or 7/16" wrench, tighten the nuts.4

Seite 3

11• To use one soil temperature sensor to provide compensation for multiple soil moisture sensors, install the temperature sensor in TEMP 1. • If the

Seite 4 - Connecting a Leaf Wetness

12Finishing the Sensor Connections to the Station1. Secure sensor cables within the cable clamps located next to the grommets.2. Secure the cable clam

Seite 5 - Temperature Sensor

13Mounting the Sensor on a PipeTo mount the sensor on a pipe, stake, or pole with outside diameter between 1" and 1-1/4" (25 mm and 31 mm),

Seite 6 - DIP Switches

14will use a default temperature of 75° F (24° C) to compensate the soil moisture readings. Finishing the Sensor Connections to the Station1. Secure s

Seite 7

15Sprinkler Irrigation• Sprinkler irrigation usually provides a more uniform distribution of water to the ground surface, but there can be great diffe

Seite 8

16• Guidelines on proper depths for specific crops and conditions can be obtained from your local farm advisor. Irrometer also maintains an excellent

Seite 9 - Mounting Station on a Pole

17• Carefully backfill the access hole with soil to eliminate any air pockets.5. You can solvent weld the 1/2” Class 315 PVC tubing to the sensor coll

Seite 10 - Cable Tie

18Troubleshooting the SensorsIf you are having problems with your station, please check all sensor cable connec-tions. Cable connections account for a

Seite 11 - Grommets

19Contacting Davis Technical SupportIf you have questions about your Leaf/Soil Station, or encounter problems installing or operating the station, ple

Seite 12 - Mounting on a Wooden Surface

2ComponentsThe Leaf/Soil Station includes the following components and hardware:Optional SensorsThe following optional sensors are available for the L

Seite 13 - Mounting on a Pipe

Product Numbers: 6345, 6345OVDavis Instruments Part Number: 07395.267 Wireless Soil Moisture, Leaf Wetness, Temperature Station 2 Installation Manual

Seite 14

3Installation StepsFor ease of installation and use of your Leaf/Soil Station, please follow steps in the order presented. • Preparing the station, pa

Seite 15

4Installing the Battery1. Insert the 3-volt lithium battery into the battery holder, matching the “+” sign on the battery with the “+” sign next to th

Seite 16 - Installation Tool

5Soil Temperature Sensor ConnectionTemporarily connect a temperature probe to the TEMP 1 terminal block connector.1. Use a pen or small screwdriver to

Seite 17

6. Setting Console/Receiver(s) to Same ID1. Put your console into Setup Mode — press and hold DONE and press the down arrow (-). • The console display

Seite 18

7Testing Station Communications1. If you are using a Soil Moisture sensor to test the station, press TEMP until you see “SOIL MOIST” displayed on the

Seite 19 - Leaf Wetness Sensor (6420)

8If the LED flashes repeatedly but your console isn’t picking up a signal anywhere in the room, it could be related to one of the following causes: •

Seite 20 - Wireless Communications

9Testing Transmission from Proposed LocationIt is very important to test reception from the proposed location before permanently mounting the Leaf/Soi