3
Data Logger Specifications
Network Interface
Network Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Base-T half duplex
Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ45
Communication Standards . . . . . . . . . . . . . . . . . . . . . . . ARP, UDP, TCP, ICMP, TFTP, DHCP, HTTP
IP Address Configuration . . . . . . . . . . . . . . . . . . . . . . . . DHCP/Manual Static IP Address Configuration
Hardware Specifications
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5VDC from console, 0.5 watts maximum consumption
Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . +14° to 140° F (-10° to 60° C)
Console Communication Baud Rate . . . . . . . . . . . . . . . . 19200 serial connection
Data Logger Archived Data
The data logger stores up to 2560 archive records (one 52-byte record per archive interval) for later transfer to your
computer. The archive records are stored in 128K of non-volatile memory; protecting the data even if the console
loses power. Maxima, minima, averages, and totals are taken over the archive interval.
Archive Record Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time/Date of Record, Inside Temperature (last or avg.), Outside
Temperature (last or avg.), Maximum Air Temperature, Minimum Air
Temperature, Wind Direction (dominant), Wind Speed (average),
Maximum Wind Speed, Rainfall (total), Rain Rate, Inside Humidity
(last), Outside Humidity (last), Barometric Pressure (last), Solar
Radiation, Hi Solar Radiation, UV, Hi UV, Evapotranspiration,
Forecast, Leaf Temperature (2), Leaf Wetness (2), Extra Humidity (2),
Extra Temperature (2), Soil Temperature (4), Soil Moisture (4), Wind
Samples, Wind Tx, Length of Archive Interval, ISS Reception
Archive Interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User-selectable from the following intervals (in minutes): 1, 5, 10, 15,
30, 60, or 120
Archive Storage Capacity (the amount of time before the archive is completely filled):
1 Minute Archive Interval . . . . . . . . . . . . . . . . . . . . . 42 hours
5 Minute Archive Interval . . . . . . . . . . . . . . . . . . . . . 8 days
10 Minute Archive Interval . . . . . . . . . . . . . . . . . . . . 17 days
15 Minute Archive Interval . . . . . . . . . . . . . . . . . . . . 26 days
30 Minute Archive Interval . . . . . . . . . . . . . . . . . . . . 53 days
60 Minute Archive Interval . . . . . . . . . . . . . . . . . . . . 106 days
120 Minute Archive Interval . . . . . . . . . . . . . . . . . . . 213 days
Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data is automatically uploaded to WeatherLink.com (see below for
details).
Using the WeatherLink software, data may be transferred
automatically from the data logger to your computer up to once an
hour using the Auto Download command. Data can be transferred
more frequently, from once a minute to once every two hours, to
support Internet uploading and other data sharing features. Only new
archive data is transferred during the download.
Data Logger Auto Uploads to WeatherLink.com
Current Conditions Upload Interval . . . . . . . . . . . . . . . . . Every 60 seconds
Archive Record Upload Interval . . . . . . . . . . . . . . . . . . . . Every 60 minutes
Website Archive Record Storage Capacity . . . . . . . . . . . 10240 archive records (4 times the storage capacity of the data
logger)
Note: The data logger storage capacity is not affected by the IP upload interval. The data logger still stores the same amount of data for download into the
WeatherLink software. If network communication is interrupted and the current conditions and archive records are not being uploaded to Weather-
Link.com, the data is still archived on the data logger. When communication is reestablished, all the records not uploaded due to communication loss are
automatically uploaded to the website.