Installation and X-320M™ Setup X-MDA-1™ User Manual
6. Attach the stripped ends of the cables to the terminal block according to the following.
Analog Cable Connections (Red Tape)
Wire Color X-320 Connection Sensor/Function
Blue Ain1 Solar Sensor
Yellow Ain2 Wind Direction
Green Ain3 UV Sensor
Red +5V RF Sensor Power
Black Agnd Analog Sensor Ground
White Do not connect No Sensor
Digital Cable Connections (Blue Tape)
Wire Color X-320 Connection Sensor/Function
Blue D I/O1 Wind Speed
Yellow D I/O 2 Rain Bucket
Green Do not connect. No Sensor
Red 5V Out Sensor Power
Black GND Sensor Ground
White Data 1-Wire Sensors (Temp, Humidity)
7. Connect the terminal block to the X-320M