Vantage PRO2
Quick
Reference
Guide
Part Number: 07395.235
Rev C (1/6/2012)
© 2012 by Davis Instruments Corp. All rights reserved.
Vantage Pro2
is a trademark of Davis Instruments Corp.
3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A.
510-732-9229 • Fax: 510-732-9188
E-mail: [email protected] • www.davisnet.com
®
®
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Reference

Vantage PRO2™Quick Reference Guide Part Number: 07395.235 Rev C (1/6/2012) © 2012 by Davis Instruments Corp. All rights reserved. Vantage Pro2™ is

Seite 2 - WIND INTRO

RAIN DAY ALARM To set an alarm: See "SET." (NOTE: Not all alarms are ava

Seite 3

BAR LAMPSPress 2ND & LAMPS to toggle between: • Backlight on. • Backlight off. If the console is running on AC power: • The backlight will rema

Seite 4 - UNITSICONS

HUMCHILLPress 2ND& CHILL to display: • Wind Chill (°F, °C)Press 2ND & UNITS to change unit of measure. All temperature-related readings

Seite 5 - TIME TICKER TAPE

CLEAR HI/LOWTo enter the high/low screen: Press HI/LOW . You will see the time & date of the DAY HIGHS for the currently selected weather variabl

Seite 6 - TEMPSETUP

HEATDEWPress 2ND& DEW to display: • Dew Point (°F, °C)Press 2ND & UNITS to change unit of measure.All temperature-related readings (insi

Seite 7

DONE GRAPH To enter the graph screen: Press a variable and then press GRAPH . You will see the graph and the min & max readings for the selected

Seite 8 - TSEDIAGNOSTICS

FORECAST ETIf you have a solar radiation sensor, press 2ND & ET to toggle between: • ET Day (0.00 in, 0.0 mm) • ET Month (0.00 in, 0.0 mm) •

Seite 9 - RAIN YR 2

WIND INTROThis “Quick Reference Guide” will provide you with abbreviated instructions for all functions of the Vantage Pro2 console. For more de-taile

Seite 10

LCDOutside Temperature Temp 1-4 (from Soil Moisture Station)ForecastIconMoon PhaseTime & Date Sunrise & Sunset Outside Humidity Wind Speed W

Seite 11 - BAR LAMPS

UNITSICONSForecast Icons. See "FORECAST."Moon Phase. The icons shown below are for the Northern Hemisphere. For the Southern Hemisphere, the

Seite 12 - HUMCHILL

TIME TICKER TAPE Press 2ND& TIME to toggle between: • Current Time & Date • Time of Sunrise & Sunset To set the time and date: 1. Pres

Seite 13

TEMPSETUP To enter setup mode: Press and hold DONE and then press ( − ). Press DONE to advance or BAR to step back through the setup messages:

Seite 14

SOLARSETUPIf you have a solar radiation sensor, press 2ND& SOLAR to display:• Solar Radiation (W/m2)To continue through the setup mode:1. ENT

Seite 15 - DONE GRAPH

TSEDIAGNOSTICS The diagnostic screen is used by our tech support staff to help diag-nose problems. If you experiencing difficulties call us at (510)

Seite 16 - FORECAST ET

RAIN YR 2NDPress RAIN YR to toggle between: • Rain Month (0.00 in, 0.0 mm) • Rain Year (0.00 in, 0.0 mm) • Rain Rate (0.00 in, 0.0 mm) Press 2ND&