This Streaming Data Logger is designed to provide an electrical interface
between a Vantage Pro2™ , Vantage Vue
®
, or Vantage Pro
®
weather sta-
tion console or Weather Envoy™ and an electrical device. You may set a
series of thresholds for various parameters that will trigger if any of them
are met (OR condition), all of them are met (AND condition), one and only
one is met (XOR condition). You may also test whether a parameter is
within (between condition) or outside of (not between condition) a certain
range, or changing at a certain rate (trending), or how far apart (or close)
two like parameters are from each other. Finally, you may also test various
parameters to see if they are reporting a valid number. This can be used to
signal a bad data connection or malfunctioning sensor.
This product also contains the functionality of the WeatherLink for Van-
tage Pro2 Serial version. Please consult the WeatherLink for Vantage Pro2
Getting Started Guide and on-line Help files for information on the use of
the WeatherLink program (including its hardware requirements and typical
installation), package contents, and optional accessories for this product.
If you plan to install this product in a Vantage Pro2 or Vantage Pro console,
use the notch in the battery door located adjacent to where the PC connec
-
tor protrudes and above the AC power connector to bring out the Connec-
tor Block wire.
If you plan to install this product in a Weather Envoy, it is recommended
that you knock out the left-most tab with the Weather Envoy's PC connec
-
tor facing you and loop the Connector Block wire around the data logger
connector to the Weather Envoy and bring it out where this tab was
removed.
Hardware Installation and Requirements
In addition to the requirements for WeatherLink, the Alarm Output capa-
bility of this product has the following additional hardware requirements.
One free serial port or one free USB port with a Serial-to-USB
adapter (Davis part # 8434) connected to a Windows PC
Computer running Windows XP
®
, Vista
®
, or 7 with at least 3 MB
free of RAM and 512 KB free of hard disk space
Small slotted screwdriver
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Introduction

1WeatherLink® for Alarm OutputAddendumIntroductionThis Streaming Data Logger is designed to provide an electrical interface between a Vantage Pro2™ ,

Seite 2

10•A Less Than or = (or low alarm) checks whether the current value is less than or equal to the value entered.•A Between alarm checks to see if the c

Seite 3

11•A True or False check is used for the Low Transmitter and Repeater Battery Status parameters, which are not numeric. This check type can also be us

Seite 4

12For guidance on how to use this alarm, it may be best to consult histori-cal weather data from WeatherLink plot data (or other sources) to deter-min

Seite 5

13“Greater Than or =” or “Less Than or =” difference. Make sure the equa-tion you create results in the check that you want. Some examples are provide

Seite 6

14• Missing: This is used to check whether a given parameter is missing or invalid.Finally, choose your Logical Grouping (whether you want to test thi

Seite 7

15the previous settings. Thus, you may notice the program takes longer times than others to set values.Notes on parameters:• Barometer Trend parameter

Seite 8 - WeatherLink 5.7.1 or later

Product Numbers: 6544 WeatherLink for Alarm Output Document Number: 07395.219 Rev. D 10/10/11 ©2011 Davis Instruments Corp. All rights reserved. Van

Seite 9

2• (Optional) Relays: You may need to obtain relays in order to switch equipment at voltages higher than 28 Volts or power levels above 10 Watts. Not

Seite 10

3Logger TypeThe software indicates the logger type and firmware revision level of the streaming data logger in the logger type box.Time Out PeriodThe

Seite 11

4can only enter this dialog box when no alarms are set. This prevents you from hiding a parameter that is set as an alarm condition.)Selecting Vantage

Seite 12

5and Humidity sensors because they always appear under “Outside Temper-ature” and “Outside Humidity” in the parameter pick list.UnitsNext, select the

Seite 13

6You may select from the following settings:Temperature:Fahrenheit (°F) or Celsius (°C)Note: Wind chill, dew point, degree-days, and temperature ind

Seite 14

7circuit mode. To utilize this function effectively, you will need to connect a device to the appropriate output so that you can tell when it is turni

Seite 15

8AdvancedNote: This description of this dialog box is valid for Streaming Data Utility versions 1.2.0 included with WeatherLink 5.7.1 or later.Delay

Seite 16

9Circuit BehaviorThis command determines whether the circuit stays open or closed when no alarms are active. The opposite behavior occurs for an activ