Davis Radiation Shield (7714) Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Thermometer Davis Radiation Shield (7714) herunter. DAVIS Radiation Shield (7714) User Manual [en] [fr] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Product number 7714
Radiation
Shield
USER
MANUAL
Davis Instruments, 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. • 510-732-9229 • www.davisnet.com
R
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Radiation

Product number 7714RadiationShieldUSERMANUALDavis Instruments, 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. • 510-732-9229 • www.davisnet.comR

Seite 2

8If you are attaching the radiation shield to the top of a post:The instructions for assembling the radiation shield differ slightly if you are mounti

Seite 3 - Radiation Shield

92. Place a #8 flat washer over the end of each of the #8 x 2 3/4” pan head screws.As long as the extra length of screw end protruding from the bottom

Seite 4 - Installation Options

10Assemble the Radiation ShieldTo assemble the radiation shield plates you will need the plates and studs assembly, as well as the rest of the plates,

Seite 5 - Attach the Sensor

11Mount the Radiation ShieldFollow the instructions below to mount the radiation shield. There are separate sections for each of the mounting options.

Seite 6 - Cable Tie

12Mounting on a Pipe:In order to mount the radiation shield onto a metal pip with outside diameter between 1” and 1 1/4” (25 mm and 31 mm), you will n

Seite 7

134. Secure the mounting bracket to the pipe using a 1/4” flat washer and a 1/4” hex nut on each end of the 1/2” U-bolts.Tighten until the mounting br

Seite 8 - Assemble the Plates and Studs

Radiation ShieldProduct Number 7714Document Number: 07395.093 Rev. D, April 19, 2013© Davis Instruments Corp. 2013. All rights reserved. Information

Seite 10 - 3/16" (4.7 mm) Drill Bit

1 Radiation Shield (7714)The radiation shield allows the temperature sensor to accurately measure air temperature without the effects of direct radiat

Seite 11

2• Four 1/4” x 1 1/2” (38 mm long) lag screwsTo attach radiation shield to a post or wall.• Three #8-32 x 1” (25 mm long) screwsTo attach radiation sh

Seite 12 - Assemble the Radiation Shield

3Attach the SensorUse the radiation shield to house an external temperature sensor (Temperature Probes with RJ Connector, p/n 7817 or 6477; or Stainle

Seite 13 - Mount the Radiation Shield

45. Once secured, adjust the position of the sensor so the probe and approximately 1/4” (6 mm) of cable protrude from the clip mounts.6. Place the cab

Seite 14 - Mounting on a Pipe:

5Attach the Support Plate to the Cover PlateTo attach the support plate, you will need the cover plate, the support plate, three #8 x 2 3/4” pan head

Seite 15 - Mounting on Top of a Post:

6Assemble the Plates and StudsTo assemble the plates and studs, you will need the cover plate assembly as well as the flat plate and close plate with

Seite 16 - Maintenance

7If you are attaching the radiation shield to the side of a post or to a wall or a pipe:1. Slide the three open plates and the two remaining closed pl

Kommentare zu diesen Handbüchern

Keine Kommentare