6
Insert the Battery
1. Insertthe3‐voltlithiumbatteryintothebatteryholder,matchingthe“+”sign
onthebatterywiththe“+”signinsidetheinterfaceshelter.
Note: It will take approximately one minute for the capacitor to charge and the unit to begin functioning.
Connect the Cable to the New Anemometer
R. M. Young 05103:
1. Openthejunctionboxontheanemometerandcutthejumperwire.(Its
locationismarked“JUMPFORCOMMONREF”.)
2. Unscrewthesealingnutonthestrainrelief.
3. Oneendofthe6‐connectorcablehasfivecoloredwires,tinnedandstripped,
andawhite(unused)wire.Feedthisendofthecablethroughthesealingnut
andthestrainreliefintothejunctionbox.
4. Connectthewirestothenumberedterminalstripasfollows:
Black . . . . . . .2
Red . . . . . . . . .3
Green . . . . . . .4
Yellow . . . . . .5
Blue . . . . . . . .6
White . . . . . . .unused
5. Replacethejunctionboxcoverandsealingnut.
NRG#40C/MAX40:
1. Useonlytheblackandbluewires.Connecttheblackwiretothe
anemometer’sblackgroundwireandthebluewiretotheanemometer’s
whitesignalwire.
2. Connecttheredandgreenwirestogether.